Why would pilot light go out in furnace?
If your furnace pilot light keeps going out, it’s likely you have a broken thermocouple in your gas furnace. The thermocouple is a rod that comes into physical contact with the flame in your system. When this component is not able to detect the flame, it will close the gas valve to prevent a gas leak in your home.
How do you reset a state select water heater?
Locate the large red button marked “Reset” at the center of your State water heater’s control circuit panel. Firmly press the “Reset” button to manually reset your water heater. Once your water heater has been reset, it may take between 12 and 24 hours for your water heater to resume normal operation.
What are the symptoms of a bad thermocouple on a furnace?
When the thermocouple is defective, even though the pilot light is burning, the main burner won’t light – no matter how cold it gets. The thermocouple looks like a piece of metal tubing smaller than a soda straw. To find it, first locate the gas control valve.
Does gas leak if the pilot light goes out?
If the pilot light goes out on a storage or instantaneous hot water heater, space heater or a ducted heater, you will not have a gas leak. This is because all modern gas appliances with pilot lights have a fail-safe device that closes off the gas to the appliance in the case when the pilot may go out.
Should the pilot light always be on in a gas furnace?
Most furnaces with electronic ignition have a device called a hot surface igniter. The difference is that the flame is only lit (by an electronic spark) when your furnace is ready for a heating cycle. When the pilot light is not needed, it is completely off, saving you money on gas.
Does a hot water heater have a reset button?
Somewhere on your electric water heater, you’ll find a reset button. It’s usually red and often located near the thermostat. It may also be hidden behind a removable metal panel on the unit—and then behind some insulation. If your water heater now has power, you’re all set.
Why does the pilot light on my furnace keep going out?
The thermocouple is the copper rod the pilot flame directly hits. Sometimes it’s referred to as the “flame sensor.”. It’s a safety mechanism that shuts the gas off should the pilot go out. If the thermocouple fails to shut off the gas, all the gas flowing through the furnace could get into your home.
What should I do if my water heater pilot light keeps going out?
The solution: First, cut off the gas supply, switch off your heater, and wait for the thermocouple to cool off. You’ll have to manually bend or straighten the thermocouple back to position.
What does a pilot light on a gas burner do?
A pilot light is a small flame inside the device that is lit at all times. This flame is used to restart the main burner and prevent gas leaks. If you have a newer appliance, don’t panic if you don’t see a pilot light. Many new devices use electric ignitions in place of pilot lights.
Why does my water heater flame keep going out?
The flame will go out if the tube is clogged with dirt or debris. Sometimes, the tube might be partially clogged and supplying very little gas for combustion- No wonder your pilot light keeps going out. The Solution: Thorough cleaning should do the trick.